C*Pix SDC2000 Instructions d'exploitation Page 142

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 366
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 141
SDC 2002
4.3. TK Config Menu
4-56
Operating Instructions - Rev. 1 / 6.2003
Select
Test Point
Mask /
CRT Gamma
Set the testpoint selector to testpoint “Film Color Correction / Mask CRT-
Gamma”. - main menu “Monitoring”, submenu “Test Pnt”
Note! From this testpoint, the signal of the Neg Film is inverted and produces
black at the frame bar.
Fig. 429: Main menu “Monitoring” / submenu “Test Pnt”
Set Matching as follows for all three channels
496 mV
at WFM for white (use R - G - B - Gain controls)
23 mV at WFM for black (use R - G - B - Lift controls)
Repeat Gain and Lift adjustments until the levels for reference white and black
are reached at the same time.
Fig. 430: Film menu, matching lift & gain
For logarithmic
calibrated Monitors